影像设备与放疗技术发展的关系越来越紧密,而包含电子射野影像系统(electronic portal imaging device, EPID)的加速器已在放疗中得到了广泛使用,EPID始于20世纪80年代,是使用荧光显像系统获得兆伏级传输图像的技术,在放疗质量控制和质量保证中应用广泛:图像方面如摆位误差验证分析等,加速器自身方面如射野、等中心验证、多叶准直器位置和到位精度验证等,剂量方面如二维三维剂量验证等,同时也有部分用于实时图像引导和剂量引导放疗的尝试。近年来,EPID设备和相关软件发展更新迅速,本文就EPID在放疗中的应用研究进展进行综述。
HTML
[1] | Estoesta RP, Attwood L, Naehrig D. Assessment of voluntary deep inspiration breath-hold with CINE imaging for breast radiotherapy[J]. J Med Imaging Radiat Oncol, 2017, 61(5): 689-694. doi: 10.1111/1754-9485.12616 | |
[2] | Li XA, Chen X, Zhang Q, et al. Margin Reduction from IGRT for Soft-Tissue Sarcoma: Secondary Analysis of RTOG0630 Results[J/OL]. Pract Radiat Oncol, 2016, 6 (4): e135-e140[2018-01-10]. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4870138. DOI: 10.1016/j.prro.2015.11.012. | |
[3] | Held M, Cremers F, Sneed PK. Assessment of image quality and dose calculation accuracy on kV CBCT, MV CBCT, and MV CT images for urgent palliative radiotherapy treatments[J]. J Appl Clin Med Phys, 2016, 17(2): 279-290. doi: 10.1120/jacmp.v17i2.6040 | |
[4] | Held M, Sneed PK, Fogh SE. Feasibility of MV CBCT-based treatment planning for urgent radiation therapy:dosimetric accuracy of MV CBCT-based dose calculations[J]. J Appl Clin Med Phys, 2015, 16(6): 458-471. doi: 10.1120/jacmp.v16i6.5625 | |
[5] | Poels K, Verellen D, Van de Vondel I, et al. Fiducial marker and marker-less soft-tissue detection using fast MV fluoroscopy on a new generation EPID: investigating the influence of pulsing artifacts and artifact suppression techniques[J/OL]. Med Phys, 2014, 41 (10): 101911[2018-01-10]. https://aapm.onlinelibrary.wiley.com/doi/abs/10.1118/1.4896116. DOI: 10.1118/1.4896116. | |
[6] | Bryant JH, Rottmann J, Lewis JH, et al. Registration of clinical volumes to beams-eye-view images for real-time tracking[J/OL]. Med Phys, 2014, 41 (12): 121703[2018-01-10]. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4235653. DOI: 10.1118/1.4900603. | |
[7] | Rottmann J, Aristophanous M, Chen A. A multi-region algorithm for markerless beam's-eye view lung tumor tracking[J]. Phy Med Biol, 2010, 55(18): 5585-5598. doi: 10.1088/0031-9155/55/18/021 | |
[8] | Cho B, Poulsen PR, Sloutsky A. First demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking[J]. Int J Radiat Oncol Biol Phys, 2009, 74(3): 859-867. doi: 10.1016/j.ijrobp.2009.02.012 | |
[9] | Rottmann J, Keall P, Berbeco R. Markerless EPID image guided dynamic multi-leaf collimator tracking for lung tumors[J]. Phys Med Biol, 2013, 58(12): 4195-5204. doi: 10.1088/0031-9155/58/12/4195 | |
[10] | Chiu TD, Yan Y, Foster R. Long-term evaluation and cross-checking of two geometric calibrations of kV and MV imaging systems for Linacs[J]. J Appl Clin Med Phys, 2015, 16(4): 306-310. doi: 10.1120/jacmp.v16i4.5140 | |
[11] | Buzurovic I, Huang K, Yu Y. A robotic approach to 4D real-time tumor tracking for radiotherapy[J]. Phys Med Biol, 2011, 56(5): 1299-1318. doi: 10.1088/0031-9155/56/5/005 | |
[12] | Sun B, Goddu SM, Yaddanapudi S. Daily QA of linear accelerators using only EPID and OBI[J]. Med Phys, 2015, 42(10): 5584-5594. doi: 10.1118/1.4929550 | |
[13] | Rowshanfarzad P, Riis HL, Zimmermann SJ, et al. A comprehensive study of the mechanical performance of gantry, EPID and the MLC assembly in Elekta linacs during gantry rotation[J/OL]. Br J Radiol, 2015, 88 (1051): 20140581[2018-01-10]. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4628515. DOI: 10.1259/bjr.20140581. | |
[14] | Huang YC, Yeh CY, Yeh JH. Clinical practice and evaluation of electronic portal imaging device for VMAT quality assurance[J]. Med Dosim, 2013, 38(1): 35-41. doi: 10.1016/j.meddos.2012.05.004 | |
[15] | 黎旦, 宾石珍, 程品晶. 非晶硅电子射野影像装置在宫颈癌剂量验证中的应用[J]. 中国医学物理学杂志, 2017, 34(3): 230-234. doi: 10.3969/j.issn.1005-202X.2017.03.003 | Li D, Bin SZ, Cheng PJ. Dose verification of cervical cancer using a-Si EPID[J]. Chin J Med Phys, 2017, 34(3): 230-234. doi: 10.3969/j.issn.1005-202X.2017.03.003 |
[16] | Woodruff HC, Fuangrod T, Rowshanfarzad P, et al. Gantry-angle resolved VMAT pretreatment verification using EPID image prediction[J/OL]. Med Phys, 2013, 40 (8): 081715[2018-01-10]. https://aapm.onlinelibrary.wiley.com/doi/abs/10.1118/1.4816384.DOI:10.1118/1.4816384. | |
[17] | Min S, Choi YE, Kwak J, et al. Practical approach for pretreatment verification of IMRT with flattening filter-free (FFF) beams using Varian Portal Dosimetry[J/OL]. J Appl Clin Med Phys, 2014, 16 (1): 4934[2018-01-10]. https://www.ncbi.nlm.nih.gov/pubmed/?term=25679149. DOI: 10.1120/jacmp.v16i1.4934. | |
[18] | Faught AM, Wu Q, Adamson J. SU-F-T-283:A Novel Device to Enable Portal Dosimetry for Flattening Filter Free Beams[J]. Med Phys, 2016, 43(6): 3527-3528. doi: 10.1118/1.4956423 | |
[19] | Pardo E, Novais JC, Molina López MY. On flattening filter-free portal dosimetry[J]. J Aappl Clin Medl Phys, 2016, 17(4): 132-145. doi: 10.1120/jacmp.v17i4.6147 | |
[20] | Chuter RW, Rixham PA, Weston SJ. Feasibility of portal dosimetry for flattening filter-free radiotherapy[J]. J Applied Clin Med Phys, 2016, 17(1): 112-120. doi: 10.1120/jacmp.v17i1.5686 | |
[21] | Willett A, Gilmore M, Rowbottom C. SU-F-T-567:Sensitivity and Reproducibility of the Portal Imaging Panel for Routine FFF QC and Patient Plan Dose Measurements[J]. Med Phys, 2016, 43(6): 3593-3594. doi: 10.1118/1.4956752 | |
[22] | Miri N, Keller P, Zwan BJ. EPID-based dosimetry to verify IMRT planar dose distribution for the aS1200 EPID and FFF beams[J]. J Appl Clin Med Phys, 2016, 17(6): 292-304. doi: 10.1120/jacmp.v17i6.6336 | |
[23] | Mijnheer BJ, González P, Olaciregui-Ruiz I, et al. Overview of 3-year experience with large-scale electronic portal imaging device-based 3-dimensional transit dosimetry[J/OL]. Pract Radiat Oncol, 2015, 5 (6): e679-e687[2018-01-10]. https://www.sciencedirect.com/science/article/pii/S1879850015002313?via%3Dihub. DOI: 10.1016/j.prro.2015.07.001. | |
[24] | Fidanzio A, Porcelli A, Azario L, et al. Quasi real time in vivo dosimetry for VMAT[J/OL]. Med Phys, 2014, 41 (6): 062103[2018-01-10]. https://aapm.onlinelibrary.wiley.com/doi/abs/10.1118/1.4875685. DOI: 10.1118/1.4875685. | |
[25] | Spreeuw H, Rozendaal R, Olaciregui-Ruiz I. Online 3D EPID-based dose verification:Proof of concept[J]. Med Phys, 2016, 43(7): 3969-3974. doi: 10.1118/1.4952729 | |
[26] | McCowan PM, Van Uytven E, Van Beek T. An in vivo dose verification method for SBRT-VMAT delivery using the EPID[J]. Med Phys, 2015, 42(12): 6955-6963. doi: 10.1118/1.4935201 | |
[27] | Millin AE, Windle RS, Lewis DG. A comparison of electronic portal dosimetry verification methods for use in stereotactic radiotherapy[J]. Phys Med, 2016, 32(1): 188-196. doi: 10.1016/j.ejmp.2015.12.001 | |
[28] | Fuangrod T, Greer PB, Woodruff HC, et al. Investigation of a real-time EPID-based patient dose monitoring safety system using site-specific control limits[J/OL]. Radiat Oncol, 2016, 11 (1): 106[2018-01-10]. https://ro-journal.biomedcentral.com/articles/10.1186/s13014-016-0682-y. DOI: 10.1186/s13014-016-0682-y. | |
[29] | Woodruff HC, Fuangrod T, Van Uytven E. First Experience With Real-Time EPID-Based Delivery Verification During IMRT and VMAT Sessions[J]. Int J Radiat Oncol Biol Phys, 2015, 93(3): 516-522. doi: 10.1016/j.ijrobp.2015.07.2271 | |
[30] | Yip S, Rottmann J, Berbeco R. The impact of cine EPID image acquisition frame rate on markerless soft-tissue tracking[J/OL]. Med Phys, 2014, 41 (6): 061702[2018-01-10]. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4032434. DOI: 10.1118/1.4873322. | |
[31] | Wang X, Chen L, Xie C. Experimental verification of a 3D in vivo dose monitoring system based on EPID[J]. Oncotarget, 2017, 8(65): 109619-109631. doi: 10.18632/oncotarget.22758 |