[1]
|
Romanyukha AA,Ignatiev EA,Vasilenko EK, et al. EPR does reconstruction for Russian nuclear workers[J].Health Phys,2000,78(1):15-20. |
[2]
|
Sholom SV,Chumak VV,Pasalskaja LF, et al. Some aspects of dosimetry of liqudatiors[J].Appl Radiat Isot,2000,52:1283-1286. |
[3]
|
Rossi AM,Wafcheck CC,Peldgrini F, et al. Electron spin resonance dosimetry of Goiáia radiation accident victims[J].Appl Radiat Isot,2000,52:1297-1303. |
[4]
|
Romanyukha AA,Degteva MO,Kozheurov VP, et al. Radiat doses from ural region[J].Nature,1996,385(5):199-200. |
[5]
|
Skvortsov VG,Ivannikov AI,Stepanenko VF, et al. Application of EPR retrospective dosimetry for large-scale accidental situation[J].Appl Radiat Isot,2000,52(5):1275-1282. |
[6]
|
Haskell EH,Hayes RB,Kenner GH, et al. An EPR dosimetry method for rapid scanning of children following a radiation accident using deciduous teeth[J].Health Phy,1999,76(2):137-144. |
[7]
|
Romanyukha AA,Regulla DF. Aspects of retrospective EPR dosimetry[J].Appl Radiat Isot,1996,477(11-12):1293-1297. |
[8]
|
Chumak V,Sholon S,Pasalskaya L, et al. Application of high precistion EPR dosimetry with tooth for reconstruction of doses to chernobyl populations[J].Radiat Prot Dosi,1999,84(14):515-520. |
[9]
|
Fattibene P,Aragno D,Onori S, et al. Effectiveness of chemical etching for background electron paramagnetic resonance signal reduction in tooth enamel[J].Appl Radiat Isot,1998,75(5):500-505. |
[10]
|
Gualtieri P,Colacicchi S,Sgattoni R, et al. The Chernobyl accident:EPR dosimetry on dental of children[J].Appl Radiat Isot,2001,55(1):71-79. |
[11]
|
Ignatiev EA,Romanyukha AA,Koshta AA, et al. Selective saturation for EPR dosimetry with tooth enamel[J].Appl Radiat Isot,1996,47(11-12):1305-1310. |
[12]
|
Koshta AA,Wieser A,Ignatiev EA, et al. New computer procedure for routine EPR-dosimetry on tooth enamel:descrption and verification[J].Appl Radiat Isot,2000,52:1287-1290. |
[13]
|
Chumak V,Pavlenko JU,Sholom S, et al. An approach to the assessment of overall uncertainty of determination of dose using an ESR technique[J].Appl Radiat Isot,1996,47(11-12):1287-1291. |
[14]
|
Nilsson J,Lund E,Lund A, et al. The effects of UV-irradiation on the ESR-dosimetry of tooth enamel[J].Appl Radiat Isot,2001,54(1):131-139. |
[15]
|
Haskell EH,Hayes RB,Kenner H, et al. Preparation-in-duced errors in EPR dosimetry of enamel:pre-and postcrushing sensitivity[J].Appl Radiat Isot,1996,47(11-12):1305-1310. |
[16]
|
Haskell EH,Hayes RB,Kenner H, et al. Electron Paramagnetic Resonance and space biodosimetry[J].Radiat Res,1997,148:s51-s59. |
[17]
|
Chumak V,Likhtarev I,Sholom S, et al. Chernobyl experience in field of retroxpective dosimetry:reconstruction of doses to the population and liquidators involved in the accident[J].Radiat Prot Dosi,1998,(1/2):91-95. |
[18]
|
Chumak V,Bailiff I,Baran N, et al. The first international intercomparison of EPR dosimetry with teeth:first results[J].Appl Radiat Isot,1996,47(11-12):1281-1286. |
[19]
|