牙釉质EPR剂量测定方法的主要影响因素分析

周莉

引用本文:
Citation:

牙釉质EPR剂量测定方法的主要影响因素分析

  • 中图分类号: R144.1

An analysis of major effect factors in enamel EPR dosimetry

  • CLC number: R144.1

  • 摘要: EPR(电子顺磁共振)剂量测定方法是回顾性测定个人辐射剂量的主要方法,它能够准确估算出很久以前发生的辐射照射事件的吸收剂量值,其理论基础是在牙釉质中,辐射所致自由基水平随着辐射剂量的增加而增加。目前,将EPR方法用于低剂量测定还存在一些困难,为了降低测量阈值,减小误差,优化方法,需要进一步研究该方法的影响因素。本文重点分析了影响牙釉质EPR剂量方法测量阈值和测量结果不确定度的主要因素,并对解决这些问题的修正方法进行了讨论。
  • [1] Regulla D. From dating to biophysics-20 years of progress in applied ESR spectroscopy[J]. Appl Radiat Isot, 2000, 52(5):1023-1030.
    [2] Aragno D, Fattibene P, Onori S. Dental radiography:tooth enamel EPR dose assessment from Rando phantom measurements[J]. Phys Med Biol, 2000, 45(9):2671-2683.
    [3] Romanyukha AA, Nagy V, Sleptchonok O, et al. Individual biodosimetry at the natural radiation background level[J].Health Phys, 2001, 80(1):71-73.
    [4] Ivannikov AI, Skvortsov VG, Stepanenko VF, et al. Tooth enamel EPR dosimetry:sources of errors and their correction[J]. Appl Radiat Isot, 2000, 52(5):1291-1296.
    [5] Ivannikov AI, Tikunov DD, Skvortsov VG, et al. Elimination of the background signal in tooth enamel samples for EPRdosimetry by means of physical-chemical treatment[J]. Appl Radiat Isot, 2001, 55(5):701-705.
    [6] Fattibene P, Aragno D, Onori S. Effectiveness of chemical etching for background electron paramagnetic resonance signal reduction in tooth enamel[J]. Health Phys, 1998, 75(5):500-505.
    [7] Ignatiev EA, Romanyukha AA, Koshta AA, et al. Selective saturation method for EPR dosimetry with tooth enamel[J].Appl Radiat Isot, 1996, 47(3):333-337.
    [8] Haskell EH, Kenner GH, Hayes RB.Electron paramagnetic resonance dosimetry of dentine following removal of organic material[J]. Health P hys, 1995, 68(4):579-584.
    [9] Bartoll J, Stosser R, Nofz M. Generation and conversion of electronic defects in calcium carbonates by UV/Vis light[J]. Appl Radiat Isot, 2000, 52(5):1099-1105.
    [10] Brik A, Baraboy V, Atamanenko O, et al. Metabolism in tooth enamel and reliability of retrospective dosimetry[J].Appl Radiat Isot, 2000, 52(5):1305-1310.
    [11] Scherbina OI, Brik AB. Temperature stability of carbonate groups in tooth enamel[J]. Appl Radiat Isot, 2000, 52(5):1071-1075.
    [12] IAEA. Use of electron paramagnetic resonance dosimetry with tooth enamel for retrospective dose assessment[M].Austria:IAEA, 2002. 25-26.
    [13] Brik A, Haskell E, Brik V, et al. Anisotropy effects of EPR signals and mechanisms of mass transfer in tooth enamel and bones[J]. Appl Radiat Isot, 2000, 52(5):1077-1083.
    [14] Zdravkova M, Crokart N, Trompier F, et al. Retrospective dosimetry after criticality accidents using low-frequency EPR:a study of whole human teeth irradiated in a mixed neutron and gamma-radiation field[J]. Radiat Res, 2003,160(2):168-173.
    [15] Haskell EH, Hayes RB, Romanyukha AA, et al. Preliminary report on the development of a virtually nondestructive additive dose technique for EPR dosimetry[J]. Appl Radiat Isot, 2000, 52(5):1065-1070.
    [16] Ishchenko SS, Vorona IP, Okulov SM, et al. 13C hyperfine interactions of CO2- in irradiated tooth enamel as studied by EPR[J]. Appl Radiat Isot, 2002, 56(6):815-819.
  • [1] 吴伟章 . 牙釉质电子顺磁共振剂量重建研究的若干进展. 国际放射医学核医学杂志, 2002, 26(4): 186-190.
    [2] 任越张慧芳胡波王婧洁王宏利原雅艺张睿凤李幼忱 . 电离辐射诱导小鼠骨电子顺磁共振信号检测的影响因素. 国际放射医学核医学杂志, 2015, 39(5): 371-374. doi: 10.3760/cma.j.issn.1673-4114.2015.05.004
    [3] 袁海娟林主戈吴春兴陈宇导周英伟张峰程木华131I治疗分化型甲状腺癌患者体内残留辐射剂量及病房辐射剂量的监测分析. 国际放射医学核医学杂志, 2019, 43(5): 400-404. doi: 10.3760/cma.j.issn.1673-4114.2019.05.003
    [4] 范亚光 . 牙釉质ESR回顾性剂量技术与剂量重建. 国际放射医学核医学杂志, 2002, 26(2): 90-92.
    [5] 白光 . 医学工作者的职业照射:剂量水平、辐射危害和个人剂量监测. 国际放射医学核医学杂志, 2005, 29(4): 171-176.
    [6] 孔令海张良安姜恩海张文艺丁艳秋苑淑渝戴光复 . 心血管病介入操作时患者受照剂量估算. 国际放射医学核医学杂志, 2010, 34(3): 183-185, 193. doi: 10.3760/cma.j.issn.1673-4114.2010.03.016
    [7] 倪园园涂彧 . 金属氧化物半导体场效应晶体管剂量探测器的工作原理及在放射治疗中的应用. 国际放射医学核医学杂志, 2008, 32(2): 125-127.
    [8] 李伟龙晚生张朝桐胡茂清梁启堂赖婵 . Radimetrics系统在CT辐射剂量评估上的初步应用. 国际放射医学核医学杂志, 2017, 41(6): 401-406. doi: 10.3760/cma.j.issn.1673-4114.2017.06.005
    [9] 李雨 . 俄罗斯核动力舰船驻泊地的辐射卫生学监督. 国际放射医学核医学杂志, 2008, 32(6): 379-381.
    [10] 陆克义李险峰 . 甲状腺疾病患者131I治疗后对他人的辐射危害评价. 国际放射医学核医学杂志, 2004, 28(5): 226-229.
  • 加载中
计量
  • 文章访问数:  1101
  • HTML全文浏览量:  86
  • PDF下载量:  2
出版历程
  • 收稿日期:  2004-03-09

牙釉质EPR剂量测定方法的主要影响因素分析

  • 300192 天津, 中国医学科学院中国协和医科大学放射医学研究所保健物理室

摘要: EPR(电子顺磁共振)剂量测定方法是回顾性测定个人辐射剂量的主要方法,它能够准确估算出很久以前发生的辐射照射事件的吸收剂量值,其理论基础是在牙釉质中,辐射所致自由基水平随着辐射剂量的增加而增加。目前,将EPR方法用于低剂量测定还存在一些困难,为了降低测量阈值,减小误差,优化方法,需要进一步研究该方法的影响因素。本文重点分析了影响牙釉质EPR剂量方法测量阈值和测量结果不确定度的主要因素,并对解决这些问题的修正方法进行了讨论。

English Abstract

参考文献 (16)

目录

    /

    返回文章
    返回