冠心病影像学检查与辐射剂量

程旭 李殿富 徐兆强 王杰 黄钢

引用本文:
Citation:

冠心病影像学检查与辐射剂量

Radiation dose of cardiac diagnostic imaging in patients with coronary artery disease

  • 摘要: 核心脏病学技术、心脏CT扫描和冠状动脉造影等是最常用的冠心病影像诊断技术,在降低冠心病的发病率和病死率方面具有重要的地位。随着这些技术的快速发展,辐射问题也越来越被专业人员和社会大众所关注,通过准确评价辐射剂量以及有效减少辐射剂量使冠心病的各种影像学技术得以更广泛、更合理的临床应用。
  • [1] Einstein AJ,Moser KW,Thompson RC,et al.Radiation dose to patients from cardiac diagnostic imaging.Circulation,2007,116(11):1290-1305.
    [2] 孟悛非,范淼.重视CT检查中的辐射剂量.中华放射学杂志,2008,42(10):1015-1017.
    [3] Thompson RC,Cullom SJ.Issues regarding radiation dosage of cardiac nuclear and radiography procedures.J Nacl Cardiol,2006,13(1):19-23.
    [4] Musolino SV,DeFranco J,Schlueck R.The ALARA principle in the context of a radiological or nuclear emergency.Health Phys,2008,94(2):109-111.
    [5] Morin RL,Gerber TC,Mccollough CH.Radiation dose in computed tomography of the heart.Circulation,2003,107(6):917-922.
    [6] 刘涛,胡可,袁芳,等.双源CT的辐射剂量研究.中国医疗设备,2008,23(10):157-158.
    [7] Rybicki FJ,Otero H J,Steigner ML,et al.Initial evaluation of coronary images from 320-detector row computed tomography.Int J Cardiovasc Imaging,2008,24(5):535-546.
    [8] Berman DS,Hachamovitch R,Shaw LJ,et al.Roles of nuclear cardiology,cardiac computed tomography,and cardiac magnetic resonance:assessment of patients with suspected coronary artery disease.J Nacl Med,2006,47(1):74-82.
    [9] Hirai N,Horiguchi J,Fujioka C,et al.Prospective versus retrospective ECG-gated 64-detector coronary CT angiography:assessment of image quality,stenosis,and radiation dose.Radiology.2008,248(2):424-430.
    [10] Trabold T,Buchgeister M,Küttner A,et al.Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating.Rofo,2003,175(8):1051-1055.
    [11] Paul JF,Abada HT.Strategies for reduction of radiation dose in cardiac multislice CT.Eur Radiol,2007,17(8):2028-2037.
    [12] Jakobs TF,Becker CR,Ohnesorge B,et al.Multislice helical CT of the heart with retrospective ECG gating:reduction of radiation exposure by ECG-controlled tube current modulation.Eur Radiol,2002,12(5):1081-1086.
    [13] Hansleiter J,Meyer T,Hadamitzky M,et al.Radiation dose estimates from cardiac multislice computed tomography in daily practice:impact of different scanning protocols on effective dose estimates.Circulation,2006,113(10):1305-1310.
    [14] Earls JP.How to use a prospective gated technique for cardiac CT.J Cardiovasc Comput Tomogr,2009,3(1):45-51.
    [15] MeCollough CH,Primak AN,Saba O,et al.Dose performance of a 64-channel dual-source CT scanner.Radiology,2007,243(3):775-784.
    [16] Hsieh J,Londt J,Vass M,et al.Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography.Med Phys,2006,33(11):4236-4248.
    [17] Charles M.UNSCEAR report 2000:sources and effects of ionizing radiation.United Nations Scientific Comittec on the Effects of Atomic Radiation.J Radiol Prot,2001,21(1):83-86.
    [18] Coles DR,Smail MA,Negus IS,et al.Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography.J Am Coll Cardiol,2006,47(9):1840-1845.
    [19] Koenig TR,Wolff D,Mettler FA,et al.Skin injuries from fluoroscopically guided procedures:part 1,characteristics of radiation injury.AIR Am J Roentgenol,2001,177(1):3-11.
    [20] Karambatsakidou A,Tornvall P,Saleh N,et al.Skin dose alarm levels in cardiac angiography procedures:is a single DAP value sufficient?.Br J Radiol,2005,78(933):803-809.
    [21] Hirshfeld JW Jr,Baiter S,Brinker JA,et al.ACCF/AHA/HRS/SCAI clinical competence statement on physician knowledge to optimize patient safety and image quality in fluoroscopically guided invasive cardiovascular procedures:a report of the American College of Cardiology Foundation/American Heart Association/American College of Physicians Task Force on Clinical Competence and Training.Circulation,2005,111(4):511-532.
  • [1] 蔡培坤梁辉晖董琴梁焕 . 640层螺旋CT冠脉成像对心肌桥-壁冠状动脉的形态学量化评价及粥样硬化相关性分析. 国际放射医学核医学杂志, 2016, 40(6): 442-446. doi: 10.3760/cma.j.issn.1673-4114.2016.06.008
    [2] 韩萍萍田月琴 . 放射性核素心肌灌注显像在急性冠状动脉综合征中的临床应用. 国际放射医学核医学杂志, 2008, 32(6): 336-340.
    [3] 赵倩李娟 . 糖尿病冠状动脉粥样硬化性心脏病的发病机制及核素心肌灌注显像的研究进展. 国际放射医学核医学杂志, 2007, 31(3): 132-135.
    [4] 杨波刘长春张勇卢汝虹99Tcm-MIBI运动负荷-静息心肌灌注显像对冠心病患者经皮腔内冠状动脉血管成形术的疗效评价. 国际放射医学核医学杂志, 2009, 33(1): 37-39. doi: 10.3760/cma.j.issn.1673-4114.2009.01.037
    [5] 李伟龙晚生张朝桐胡茂清梁启堂赖婵 . Radimetrics系统在CT辐射剂量评估上的初步应用. 国际放射医学核医学杂志, 2017, 41(6): 401-406. doi: 10.3760/cma.j.issn.1673-4114.2017.06.005
    [6] 邵晓梁王跃涛 . 心肌灌注显像与冠状动脉钙化积分对冠心病风险评估的研究现状及相互关系. 国际放射医学核医学杂志, 2011, 35(2): 99-103. doi: 10.3760/cma.j.issn.1673-4114.2011.02.008
    [7] 孙晓昕田月琴 . PET-CT在冠状动脉疾病的临床应用. 国际放射医学核医学杂志, 2008, 32(3): 150-153.
    [8] 孙茉茉李剑明 . PET心肌灌注显像及其定量分析的研究进展. 国际放射医学核医学杂志, 2017, 41(6): 423-429. doi: 10.3760/cma.j.issn.1673-4114.2017.06.008
    [9] 周玉祥蓝博文黄春榆饶红萍李丽红代海洋 . 64排螺旋CT冠状动脉血管成像诊断冠状动脉-肺动脉瘘的应用价值. 国际放射医学核医学杂志, 2016, 40(1): 26-30. doi: 10.3760/cma.j.issn.1673-4114.2016.01.006
    [10] 石洪成 . 核心脏病学的应用进展. 国际放射医学核医学杂志, 2007, 31(6): 362-365,369.
  • 加载中
计量
  • 文章访问数:  1900
  • HTML全文浏览量:  309
  • PDF下载量:  3
出版历程
  • 收稿日期:  2009-06-06

冠心病影像学检查与辐射剂量

  • 1. 南京医科大学第一附属医院核医学科, 南京 210029;
  • 2. 南京医科大学第一附属医院心脏科, 南京 210029;
  • 3. 南京医科大学第一附属医院放射科, 南京 210029;
  • 4. 上海交通大学仁济医院核医学科, 上海临床核医学研究所, 上海 200001

摘要: 核心脏病学技术、心脏CT扫描和冠状动脉造影等是最常用的冠心病影像诊断技术,在降低冠心病的发病率和病死率方面具有重要的地位。随着这些技术的快速发展,辐射问题也越来越被专业人员和社会大众所关注,通过准确评价辐射剂量以及有效减少辐射剂量使冠心病的各种影像学技术得以更广泛、更合理的临床应用。

English Abstract

参考文献 (21)

目录

    /

    返回文章
    返回