《“健康中国2030”规划纲要》及《中国制造2025》等一系列重大政策的相继出台,推动了国产医疗设备行业的发展[1-2],使国产医学影像设备的占有率得到提高。同时,随着核医学优势在肿瘤、神经、心脏等领域的不断体现,其临床认可度不断提升[3-4],国产核医学影像设备行业已逐渐发展成熟。截至目前,我国已有多家国产核医学影像设备企业,并已取得一定的成绩。
国产核医学影像设备的发展现状
Development status of domestic nuclear medicine imaging equipment
-
摘要: 近年来,国家对医疗机构建设和医疗行业发展的不断投入,对医疗资源配置的优化以及对医疗卫生体制改革的不断深入,使得国产医疗设备得到创新发展及推广应用。同时核医学普及率及临床需求的逐渐提高,使国产核医学设备数量大幅增加,在PET/CT、PET/MR及SPECT/CT方面均取得了一定的创新及发展。笔者就目前国产核医学影像设备的发展情况及现状进行综述。
-
关键词:
- 核医学 /
- 正电子发射断层显像术 /
- 体层摄影术,X线计算机 /
- 体层摄影术,X线计算机,单光子 /
- 磁共振成像
Abstract: In recent years, the state has continuously invested in constructing medical institutions and developing the medical industry. With the optimization of the allocation of medical resources and the continuous deepening of the medical and health system reform, China's domestic medical equipment has been innovatively developed and popularized. At the same time, according to the popularity of nuclear medicine and the gradual improvement of clinical demand, domestic nuclear medicine equipment has increased significantly, and has made certain innovation and development in PET/CT, PET/MR and SPECT/CT. The authors review the development and current situation of domestic nuclear medicine imaging equipment. -
[1] 都勇, 王大遒, 冯莉, 等. 辽宁省基层医疗机构国产医疗器械配置现状及障碍因素的现象学研究[J]. 中国医学装备, 2019, 16(6): 93−98. DOI: 10.3969/J.ISSN.1672-8270.2019.06.026.
Du Y, Wang DQ, Feng L, et al. Phenomenological study on current situations and obstacle factors of the configuration of domestic medical devices in primary medical institutions of Liaoning province[J]. China Med Equip, 2019, 16(6): 93−98. DOI: 10.3969/J.ISSN.1672-8270.2019.06.026.[2] 都勇, 王大遒, 张军, 等. 区域国产医疗器械“四位一体”阶梯化配置方案的构建[J]. 中国医学装备, 2020, 17(6): 128−132. DOI: 10.3969/J.ISSN.1672-8270.2020.06.032.
Du Y, Wang DQ, Zhang J, et al. Construction of "quaternity step" configuration scheme of domestically medical devices at a region[J]. China Med Equip, 2020, 17(6): 128−132. DOI: 10.3969/J.ISSN.1672-8270.2020.06.032.[3] 许书钰, 曹大泉, 梁唯真, 等. 单光子发射型电子计算机断层扫描设备的研究进展[J]. 中国医学装备, 2022, 19(10): 156−161. DOI: 10.3969/J.ISSN.1672-8270.2022.10.034.
Xu SY, Cao DQ, Liang WZ, et al. Research progress of SPECT devices[J]. China Med Equip, 2022, 19(10): 156−161. DOI: 10.3969/J.ISSN.1672-8270.2022.10.034.[4] 张志豪, 朱晨亿, 丛容, 等. 放射性金属核素及其核医学应用[J]. 国际医学放射学杂志, 2023, 46(3): 333−339, 347. DOI: 10.19300/j.2023.Z20334.
Zhang ZH, Zhu CY, Cong R, et al. Radiometallic nuclides and their applications in nuclear medicine[J]. Int J Med Radiol, 2023, 46(3): 333−339, 347. DOI: 10.19300/j.2023.Z20334.[5] Couceiro M, Ferreira NC, Fonte P. Sensitivity assessment of wide axial field of view PET systems via monte Carlo simulations of NEMA-like measurements[J]. Nucl Instrum Methods Phys Res A, 2007, 580(1): 485−488. DOI: 10.1016/j.nima.2007.05.145. [6] 凌文嘉, 林晓琴, 龚琬玲, 等. 基于uEXPLORER PET-CT机的NEMA标准性能检测方法[J]. 中国医学物理学杂志, 2022, 39(9): 1167−1172. DOI: 10.3969/j.issn.1005-202X.2022.09.018.
Ling WJ, Lin XQ, Gong WL, et al. NEMA standard-based performance test for uEXPLORER PET-CT machine[J]. Chin J Med Physics, 2022, 39(9): 1167−1172. DOI: 10.3969/j.issn.1005-202X.2022.09.018.[7] 蒋梨, 黄衍超, 李洪生, 等. 基于NEMA NU 2-2007标准测试国产uEXPLORER PET系统性能[J]. 中国医学影像技术, 2021, 37(11): 1725−1730. DOI: 10.13929/j.issn.1003-3289.2021.11.031.
Jiang L, Huang YC, Li HS, et al. Testing performance of domestic uEXPLORER PET system according to NEMA NU 2-2007 standards[J]. Chin J Med Imaging Technol, 2021, 37(11): 1725−1730. DOI: 10.13929/j.issn.1003-3289.2021.11.031.[8] 牟兴宇, 秦洋洋, 李明, 等. 重建方法对Neuwise PET/CT 18F-FDG全身显像图像质量及SUV的影响[J]. 中国医疗设备, 2022, 37(5): 82−85. DOI: 10.3969/j.issn.1674-1633.2022.05.017.
Mu XY, Qin YY, Li M, et al. Effect of reconstruction methods on whole-body image quality and SUV of the Neuwise PET/CT 18F-FDG[J]. China Med Devices, 2022, 37(5): 82−85. DOI: 10.3969/j.issn.1674-1633.2022.05.017.[9] 曾天翼, 宋少莉, 吕力琅. 一体化PET/MR技术的发展及临床应用[J]. 肿瘤影像学, 2019, 28(4): 276−282. DOI: 10.19732/j.cnki.2096-6210.2019.04.013.
Zeng TY, Song SL, Lyu LL. Technical progress and clinical application of integrated PET/MR?[J]. Oncoradiology, 2019, 28(4): 276−282. DOI: 10.19732/j.cnki.2096-6210.2019.04.013.[10] 陈兴, 赵军. PET/MR的衰减校正技术[J]. 国际放射医学核医学杂志, 2018, 42(4): 352−356. DOI: 10.3760/cma.j.issn.1673-4114.2018.04.012.
Chen X, Zhao J. Overview of PET/MR attenuation correction[J]. Int J Radiat Med Nucl Med, 2018, 42(4): 352−356. DOI: 10.3760/cma.j.issn.1673-4114.2018.04.012.[11] Chen SG, Gu YS, Yu HJ, et al. NEMA NU2-2012 performance measurements of the United Imaging uPMR790: an integrated PET/MR system[J]. Eur J Nucl Med Mol Imaging, 2021, 48(6): 1726−1735. DOI: 10.1007/s00259-020-05135-9. [12] 刘自来, 田嘉禾, 张锦明, 等. 国产BHP6601型SPECT固有性能测试[J]. 同位素, 2004, 17(2): 93−98. DOI: 10.3969/j.issn.1000-7512.2004.02.007.
Liu ZL, Tian JH, Zhang JM, et al. The intrinsic function measurement of first domestic BHP6601 SPECT[J]. J Isot, 2004, 17(2): 93−98. DOI: 10.3969/j.issn.1000-7512.2004.02.007.[13] 张书文, 田嘉禾, 刘自来, 等. 国产BHP6601型SPECT的临床应用[J]. 同位素, 2005, 18(3): 186−188, 163. DOI: 10.3969/j.issn.1000-7512.2005.03.015.
Zhang SW, Tian JH, Liu ZL, et al. Clinical application of domestica manufactured BHP6601 SPECT[J]. J Isot, 2005, 18(3): 186−188, 163. DOI: 10.3969/j.issn.1000-7512.2005.03.015.[14] 姚树林, 窦寰宇, 王新强, 等. 2种SPECT联合质量控制与等效性比较[J]. 医疗卫生装备, 2017, 38(8): 75−78, 90. DOI: 10.7687/j.issn1003-8868.2017.08.075.
Yao SL, Dou HY, Wang XQ, et al. Comparison of joint quality control and equivalence between two SPECT machines[J]. Chin Med Equip, 2017, 38(8): 75−78, 90. DOI: 10.7687/j.issn1003-8868.2017.08.075.[15] 赵振峰, 王雪梅, 王瑞, 等. NET632型SPECT与Symbia T16型SPECT/CT在全身骨骼显像中的图像对比[J]. 国际放射医学核医学杂志, 2020, 44(2): 87−91. DOI: 10.3760/cma.j.issn.1673-4114.2020.02.003.
Zhao ZF, Wang XM, Wang R, et al. Comparing the NET632 SPECT and the Symbia T16 SPECT/CT images in whole-body bone scintigraphy[J]. Int J Radiat Med Nucl Med, 2020, 44(2): 87−91. DOI: 10.3760/cma.j.issn.1673-4114.2020.02.003.
计量
- 文章访问数: 1919
- HTML全文浏览量: 1454