[1] Gudowska I, Brahme A, Andreo P, et al. Calculation of absorbed dose and biological effectiveness from photonuclear reactions in a bremsstrahlung beam of end point 50 MeV[J]. Phys Med Biol, 1999,44(9):2099-2125.
[2] Strauss LG, Clorius JH, Kimmig B, et al. Imaging positron emitting radionuclides generated during radiation therapy[J]. Eur J Radiol,1989, 9(4):200-202.
[3] Almen A, Ahlgren L, Mattsson S. Absorbed dose to technicians due to induced activity in linear accelerators for radiation therapy[J]. Phys Med Biol, 1991, 36(6):815-822.
[4] Endo A, Harada Y, Kawasaki K, et al. Measurement of depth distributions of (3)H and (14)C induced in concrete shielding of an electron accelerator facility[J]. Appl Radiat Isot, 2004, 60(6):955-958.
[5] Marco S, Luisa U. Investigation of induced radioactivity in the CERN large electron positron collider for its decommissioning[J]. Nucl Instrum Methods Phys Res, 2004, 526(3):510-536.
[6] Robert C, Donald C, Keran O, et al. Environmental Radiological Aspects of Particle Accelerators[J]. NCRP Report, 2003, 144:320-359.
[7] Rokni SH, Fasso A, Gwise T, et al. Induced radioactivity of materials by stray radiation fields at an electron accelerator[J]. Nucl Instrum Methods Phys Res, 2002, 484(1-3):680-689.
[8] Stevenson GR. Induced activity in accelerator structures, air and water[J]. Radiat Prot Dos, 2001, 96(4):373-380.
[9] Yashima H, Uwamino Y, Sugita H, et al. Induced radioactivity in Cu targets produced by high-energy heavy ions and the corresponding estimated photon dose rates[J]. Radiat Prot Dos, 2004, 112(2):195-208.
[10] Ban S, Nakamura H, Sato T, et al. Radioactivity induced in a 2.5 Ge V electron beam dump[J]. Radiat Prot Dos, 2001, 93(3):231-236.
[11] Stevenson GR. Experimental verification of particle distributions in proton-induced cascades[J]. Adv Space Res, 1996,17(2):95-104.
[12] Weeks KJ, O'Shea PG. Production of radioisotopes by direct electron activation[J]. Med Phys, 1998, 25(4):488-492.
[13] Ewen K, Lauber-Altmann I. Activation of solid materials in a medical linear electron accelerator[J]. Rontgenblatter, 1987, 40(6):185-190.
[14] Endo A, Kikuchi M, Izawa S, et al. Characteristics of the chemical from of 11C, 13N, and 150 induced in air by the operation of a 100 MeV electron linear accelerator[J]. Health Phys, 1995, 68(1):80-88.
[15] Agosteo S. Radiation protection at medical accelerators[J]. Radiat Prot Dos, 2001, 96(4):393-406.
[16] Silari M. Special radiation protection aspects of medical accelerators[J]. Radiat Prot Dos, 2001, 96(4):381-392.