[1] Harris B, Bailey D, Miles S, et al.  Objective Analysis of Tomographic Ventilation-Perfusion Scintigraphy in Pulmonary Embolism[J]. Am J Respir Crit Care Med, 2007, 175(11): 1173-1180.   doi: 10.1164/rccm.200608-1110OC
[2] Bajc M, Chen Y, Wang J, et al.  Identifying the heterogeneity of COPD by V/P SPECT: a new tool for improving the diagnosis of parenchymal defects and grading the severity of small airways disease[J]. Int J Chron Obstruct Pulmon Dis, 2017, 12: 1579-1587.   doi: 10.2147/COPD.S131847
[3] Galiè N, Humbert M, Vachiery JL, et al.  2015 ESC/ERS Guidelines for the Diagnosis and Treatment of Pulmonary Hypertension: The Joint Task Force for the Diagnosis and Treatment of Pulmonary Hypertension of the European Society of Cardiology (ESC) and the European Respiratory Society (ERS): Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC), International Society for Heart and Lung Transplantation (ISHLT)[J]. Eur Heart J, 2016, 37(1): 67-119.   doi: 10.1093/eurheartj/ehv317
[4] 中华医学会放射学分会心胸学组.  低剂量螺旋CT肺癌筛查专家共识[J]. 中华放射学杂志, 2015, (5): 328-335.   doi: 10.3760/cma.j.issn.1005-1201.2015.05.003
Cardiothoracic Group of Radiology Society of Chinese Medical Association.  Low dose spiral CT lung cancer screening experts consensus[J]. Chin J Radiol, 2015, (5): 328-335.   doi: 10.3760/cma.j.issn.1005-1201.2015.05.003
[5]

Arvola S, Jambor I, Kuisma A, et al. Comparison of standardized uptake values between 99mTc-HDP SPECT/CT and 18F-NaF PET/CT in bone metastases of breast and prostate cancer[J/OL]. EJNMMI Res, 2019, 9(1): 6[2019-02-27]. https://ejnmmires.springeropen.com/articles/10.1186/s13550-019-0475-z. DOI: 10.1186/s13550-019-0475-z.

[6] Suga K, Kawakami Y, Koike H, et al.  Lung ventilation-perfusion imbalance in pulmonary emphysema: assessment with automated V/Q quotient SPECT[J]. Ann Nucl Med, 2010, 24(4): 269-277.   doi: 10.1007/s12149-010-0369-7
[7] King GG, Harris B, Mahadev S.  V/Q SPECT: utility for investigation of pulmonary physiology[J]. Semin Nucl Med, 2010, 40(6): 467-473.   doi: 10.1053/j.semnuclmed.2010.07.006
[8] Suga K, Kawakami Y, Zaki M, et al.  Clinical utility of co-registered respiratory-gated 99mTc-Technegas/MAA SPECT-CT images in the assessment of regional lung functional impairment in patients with lung cancer[J]. Eur J Nucl Med Mol Imaging, 2004, 31(9): 1280-1290.   doi: 10.1007/s00259-004-1558-1
[9] Takenaka D, Ohno Y, Koyama H, et al.  Co-registered perfusion SPECT/CT: Utility for prediction of improved postoperative outcome in lung volume reduction surgery candidates[J]. Eur J Radiol, 2010, 74(3): 465-472.   doi: 10.1016/j.ejrad.2009.03.008
[10] Ohno Y, Koyama H, Takenaka D, et al.  Coregistered Ventilation and Perfusion Spect Using Krypton-81m and Tc-99m-Labeled Macroaggregated Albumin With Multislice CT: utility for Prediction of Postoperative Lung Function in Non-Small Cell Lung Cancer Patients[J]. Acad Radiol, 2007, 14(7): 830-838.   doi: 10.1016/j.acra.2007.03.013
[11] Brendle C, Kupferschlager J, Nikolaou K, et al.  Is the standard uptake value (SUV) appropriate for quantification in clinical PET imaging? —Variability induced by different SUV measurements and varying reconstruction methods[J]. Eur J Radiol, 2015, 84(1): 158-162.   doi: 10.1016/j.ejrad.2014.10.018
[12] Sando Y, Inoue T, Nagai R, et al.  Ventilation/perfusion ratios and simultaneous dual-radionuclide single-photon emission tomography with krypton-81m and technetium-99m macroaggregated albumin[J]. Eur J Nucl Med, 1997, 24(10): 1237-1244.   doi: 10.1007/s002590050147
[13] Suga K, Kawakami Y, Koike M, et al.  Characteristic crescentic subpleural lung zones with high ventilation (V)/perfusion (Q) ratios in interstitial pneumonia on V/Q quotient SPECT[J]. Nucl Med Commun, 2009, 30(11): 881-889.   doi: 10.1097/MNM.0b013e328330571d