[1] Zanzonico P. Positron emission tomography:a review of basic principles scanner design and performance, and current systems[J]. Semin Nucl Med, 2004, 34(2):87-111.
[2] Kinahan PE, Hasegawa BH, Beyer T. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners[J]. Semin Nucl Med, 2003, 33(3):166-179.
[3] Nakamoto Y, Osman M, Cohade C, et al. PET/CT:comparison of quantitative tracer uptake between germanium and CT transmission attenuation-corrected images[J]. J Nucl Med, 2002, 43(9):1137-1143.
[4] Dizendorf E, Hany TF, Buck A, et al. Cause and magnitude of the error induced by oral CT contrast agent in CT-based attenuation correction of PET emission studies[J]. J Nucl Med, 2003, 44(5):732-738.
[5] Kamel E, Hany TF, Burger C, et al. CT vs 68Ge attenuation correction in a combined PET/CT system:evaluation of the effect of lowering the CT tube current[J]. Eur J Nucl Med, 2002, 29(3):346-350.
[6] Goerres GW, Hany TF, Kamel E, et al. Head and neck imaging with PET and PET/CT:artefacts from dental metallic implants[J]. Eur J Nucl Med, 2002, 29(3):367-370.
[7] Goerres GW, Ziegler SI, Burger C, et al. Artifacts at PET and PET/CT caused by metallic hip prosthetic material[J]. Radiology, 2003,226(2):577-584.
[8] Difilippo FP, Brunken RC. Do implanted pacemaker leads and ICD leads cause metal-related artifact in cardiac PET/CT?[J]. J Nucl Med, 2005, 46(3):436-443.
[9] Antoch G, Kuehl H, Kanja J, et al. Dual-modality PET/CT scanning with negative oral contrast agent to avoid artifacts:introduction and evaluation[J]. Radiology, 2004, 230(3):879-885.
[10] Antoch G, Freudenberg LS, Egelhof T, et al. Focal tracer uptake:a potential artifact in contrast-enhanced dual-modality PET/CT scans[J]. J Nucl Med, 2002, 43(10):1339-1342.
[11] Yau YY, Chan WS, Tam YM, et al. Application of intravenous contrast in PET/CT:does it really introduce significant attenuation correction error?[J]. J Nucl Med, 2005, 46(2):283-291.
[12] Beyer T, Antoch G, Bockisch A, et al. Optimized intravenous contrast administration for diagnostic whole-body 18F-FDG PET/CT[J]. JNucl Med, 2005, 46(3):429-435.
[13] Bockisch A, Beyer T, Antoch G, et al. Positron emission tomography/computed tomography-imaging protocols, artifacts, and pitfalls[J].Mol Imaging Biol, 2004, 6(4):188-199.
[14] Nakamoto Y, Chin BB, Kraitchman DL, et al. Effects of nonionic intravenous contrast agents at PET-CT imaging:Phantom and canine studies[J]. Radiology, 2003, 227(3):817-824.
[15] Beyer T, Antoch G, Muller S, et al. Acquisition protocol considerations for combined PET/CT Imaging[J]. J Nucl Med, 2004, 45(suppl 1):25s-35s.
[16] Nakamoto Y, Tatsumi M, Cohade C, et al. Accuracy of image fusion of normal upper abdominal organs visualized with PET/CT[J]. Eur J Nucl Med Mol Imaging, 2003, 30(4):597-602.
[17] Osman MM, Cohade C, Nakamoto Y, et al. Clinically significant inaccurate localization of lesions with PET/CT:frequency in 300patients[J]. J Nucl Med, 2003, 44(2):240-243.
[18] Goerres GW,Kamel E, Seifert B, et al. Accuracy of image coregistration of pulmonary lesions in patients with non-small cell lung cancer using an integrated PET/CT system[J]. J Nucl Med, 2002, 43(11):1469-1475.
[19] Goerres GW, Kamel E, Heidelberg TN, et al. PET-CT image coregistration in the thorax:influence of respiration[J]. Eur J Nucl Med,2002, 29(3):351-360.
[20] Beyer T, Blodgett T, Blodgett T, et al. Dual-modality PET-CT imaging:the effect of respiratory motion on combined image quality in clinical oncology[J]. Eur J Nucl Med Mol Imaging, 2003, 30(4):588-596.
[21] Osman MM, Cohade C, Nakamoto Y, et al. Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT[J]. EurJ Nucl Med Mol Imaging, 2003, 30(4):603-606.
[22] Nehmeh SA, Erdi YE, Pan T, et al. Quantitation of respiratory motion during 4D-PET-CT acquisition[J]. Med Phys, 2004, 31(6):1333-1338.
[23] Nehmeh SA, Erdi YE, Pan T, et al. Four-dimensional (4D) PET/CTimaging of the thorax[J]. Med Phys, 2004, 31(12):3179-3186.
[24] Nakamoto Y, Chin BB, Cohade C, et al. PET/CT:artifacts caused by bowel motion[J]. Nucl Med Commun, 2004, 25(3):221-225.
[25] Visvikis D, Costa DC, Croasdale I, et al. CT-based attenuation correction in the calculation of semi-quantitative indices of [18F]FDG uptake in PET[J]. EurJ Nucl Med Mol Imaging, 2003, 30(3):344-353.
[26] Cook GJR, Wegner EA, Fogelman I. Pitfalls and artifacts in 18FDG PET and PET/CT oncologic imaging[J]. Semin Nucl Med, 2004, 34(2):122-133.