[1] Dieter R. From dating to biophysics-20 years of progress in applied ESR spectroscopy[J]. Appl Radiat Isot, 2000, 52:1023-1030.
[2] Ivannikov AI, Skvortsov VG, Stepanenko VF, et al. EPR tooth enamel dosimetry:optimization of the automated spectra deconvolution routine[J]. Health Phys, 2001, 81:124-137.
[3] Ostrowski K, Dziedzic-Gostawska A, Stachowich W, et al. Stable radiation-induced paramagnetic entities in tissue mineral and their use in calcified tissue research[A]. In:Pryar W (Ed), Free Radicals in Biology[M], Vol 4, Academic Press, New York, 1980. 321-344.
[4] Ivannikov AI, Tikunov DD, Skvortsov VG, et al. Elimination of the background signal in tooth enamel samples for EPR-dosimetry by means of physical-chemical treatment[J]. Appl Radiat Isot, 2001, 55:701-705.
[5] Haskell EH, Hayes RB, Kenner GH, et al. Electron paramagnetic resonance techniques and space biodosimetry[J]. Radia Res, 1997, 148:S51-S59.
[6] Fattibene P, Aragno D, Onori S, et al. Effectiveness of chemical etching for background electron paramagnetic resonance signal reduction in tooth enamel[J]. Health Phys, 1998, 75:500-505.
[7] Romanyukha AA, Ignatiev EA, Vasilenko EK, et al. Geographic variations in the EPR spectrum of tooth enamel[J]. Radiat Prot Dosim, 1999, 84:445-450.
[8] Romanyukha AA, Desrosiers MF, Regulla DF. Current issues on EPR dose reconstruction in tooth enamel[J]. Appl Radiat Isot, 2000, 52:1265-1273.
[9] Chumk V, Bailiff I, Baran N, et al. The first international intercomparison of EPR dosimetry with teeth:first results[J]. Appl Radiat Isot, 1996, 47:1281-1286.
[10] Haskell EH, Hayes RB, Kenner GH, et al. Achievable resolution and accuracy in EPR dosimetry of tooth enamel[J]. Radiat Prot Dosim, 1999, 84:525-535.
[11] Ignatiev EA, Romanyukha AA, Koshta AA, et al. Selective saturation method for EPR dosimetry with tooth enamel[J]. Appl Radiat Isot, 1996, 47:333-337.
[12] Dubovsky S, Kirillov V. Reconstruction of individual absorbed doses by tooth enamel on the base of non-linear simulation of their EPR spectra[J]. Appl Radiat Isot, 2001, 54:833-837.
[13] Egersdörfer S, Wieser A, Muller A. Tooth enamel as a detector material for retrospective EPR dosimetry[J]. Appl Radiat Isot, 1996, 47:1299-1303.
[14] Koshta AA, Wieser A, Ignatiev EA, et al. New computer procedure for routine EPR dosimetry on tooth enamel:description and verification[J]. Appl Radiat Isot, 2000, 52:1287-1290.
[15] Ivannikov AI, Skovortsov VG, Stepanenko VF, et al. Wide scale EPR retrospective dosimetry, results and problems[J]. Radiat Prot Dosim, 1997, 71:175-180.
[16] Nilsson J, Lund E, Lund A. The effects of UV-irradiation on the ESR dosimetry of tooth enamel[J]. Appl Radiat Isot, 2001, 54:131-139.
[17] Sholom SV, Haskell EH, Hayes RB, et al. Influenced crushing and additive irradiation procedures on EPR dosimetry of tooth enamel[J]. Radiat Meas, 1998, 29:101-111.
[18] Yamanaka C, Ikeya M, Hara H. ESR cavities for in vivo dosimetry of tooth enamel[J]. Appl Radiat Isot, 1993, 44:77-80.
[19] Miyake M, Liu KJ, Tadeusz M, et al. In vivo EPR dosimetry of accidental exposures to radiation:experimental results indicating the feasibility of practical use in human subjects[J]. Appl Radiat Isot, 2000, 52:1031-1038.
[20] Wieser A, Onori S, Aragno D, et al. Comparison of sample preparation and signal evaluation methods for EPR analysis of tooth enamel[J]. Appl Radiat Isot, 2000, 52:1059-1064.
[21] Seltzer SM, Romanyukha AA, Nagy V. Monte Carlo calculations of the dose distribution in teeth due to internal exposure from 90Sr:application to EPR tooth dosimetry[J]. Radiat Prot Dosim. 2001, 93:245-260.