Abstract:
Objective To investigate the factors influencing setup errors in prostate cancer patients receiving radiotherapy under the guidance of fan-beam computed tomography (FBCT) images.
Methods A retrospective analysis was conducted on 24 prostate cancer patients treated with volumetric modulated arc therapy at the Third Hospital of Peking University from May 2024 to March 2025, comprising a total of 25 treatment sessions. A total of 600 FBCT image sets were collected. Rigid registration was used to match and calibrate the errors for each FBCT session. The setup errors were recorded in the vertical (VRT), longitudinal (LNG), and lateral (LAT) directions, as well as the rotational errors in yaw, pitch, and roll. The bladder and rectal volumes were automatically segmented and recorded. A linear regression model was employed to analyze the relationship between setup errors and patient age, height, weight, BMI, bladder volume, and rectal volume.
Results After image-guided correction via rigid registration, the couch calibration values in the VRT, LNG, and LAT directions were (0.16±0.53) cm, (0.06±0.70) cm, and (0.21±0.51) cm, respectively. The rotational calibration values in the yaw, pitch, and roll directions were (−0.17±1.38)°, (0.39±1.44)°, and (−0.05±1.02)°, respectively. Significant positive correlations were observed between VRT errors and age, height, weight, and rectal volume. LNG errors showed significant negative correlations with weight and BMI but a positive correlation with rectal volume. LAT errors were positively correlated with age and bladder volume and negatively correlated with height. Yaw errors were positively correlated with age, weight, and BMI. Pitch errors were negatively correlated with age, height, and weight but positively correlated with bladder volume. Roll errors were positively correlated with age, height, and rectal volume. Bladder volume gradually decreased as treatment fractions progressed (β=−2.893, P < 0.001), while rectal volume showed no significant change (β=0.118, P=0.162).
Conclusion Key factors positively correlated with setup errors include age, rectal volume, and BMI, while height and weight showed negative correlations. Reduced bladder filling capacity was observed over the treatment course. Setup errors result from the combined effects of multiple factors.