FBCT图像引导下前列腺癌患者放疗摆位误差的影响因素

Influencing factors of radiotherapy setup errors in prostate cancer patients under FBCT image guidance

  • 摘要:
    目的 研究扇形束CT(FBCT)图像引导下前列腺癌患者放疗摆位误差的影响因素。
    方法 该研究为单中心回顾性观察性研究。回顾性分析2024年5月至2025年3月北京大学第三医院收治的24例接受25次容积弧形调强放疗的前列腺癌患者年龄(68.0±6.6)岁的600套治疗前FBCT图像。将治疗前获取的FBCT图像与计划CT图像进行刚性配准,获得各方向的摆位误差,并据此进行治疗床位置校正。记录每次FBCT图像配准获得的垂直(VRT)、头脚(LNG)、左右(LAT)、偏航角(Yaw)、俯仰角(Pitch)、翻滚角(Roll)方向的摆位误差,同时采用自动勾画软件分割并勾画膀胱和直肠体积。采用单因素线性回归模型分析放疗的摆位误差与患者年龄、身高、体重、体重指数(BMI)、膀胱体积、直肠体积之间的关系;采用线性混合效应模型分析器官体积与治疗分次之间的关系。
    结果 经刚性配准进行图像引导校正后,VRT、LNG和LAT方向摆位误差分别为(0.16±0.53)、(0.06±0.70)、(0.21±0.51)cm;Yaw、Pitch和Roll方向摆位误差分别为(−0.17±1.38)°、(0.39±1.44)°、(−0.05±1.02)°。单因素线性回归模型分析结果显示:VRT方向摆位误差与患者年龄、身高、体重及直肠体积呈正向关联(β=0.0186、0.0212、0.0041、0.0069,P分别为<0.01、<0.01、<0.05和<0.01);LNG方向摆位误差与患者身高、体重及BMI呈负向关联(β=−0.0126、−0.0101、−0.0316,P分别为<0.05、<0.01和<0.01),与直肠体积呈正向关联(β=0.0047,P<0.01);LAT方向摆位误差与患者年龄、膀胱体积及直肠体积呈正向关联(β=0.0096、0.0005、0.0024,P分别为<0.01、<0.05和<0.05),与身高呈负向关联(β=−0.0099,P<0.01);Yaw方向摆位误差与患者年龄、身高、体重及BMI呈正向关联(β=0.0518、0.0235、0.0310、0.1542,P分别为<0.01、<0.05、<0.01和<0.01);Pitch方向摆位误差与患者年龄、身高及体重呈负向关联(β=−0.0344、−0.0570、−0.0205,均P<0.01),与膀胱体积呈正向关联(β=0.0028,P<0.01);Roll方向摆位误差与患者年龄、身高及直肠体积呈正向关联(β=0.0161、0.0252、0.0054,P分别为<0.01、<0.01和<0.05)。随着治疗分次的增加,膀胱体积呈下降趋势(β=−2.8930,P<0.01),直肠体积无明显变化(β=0.1180,P=0.12)。
    结论 FBCT图像引导下前列腺癌患者放疗不同方向的摆位误差与患者特征及器官体积存在关联。

     

    Abstract:
    Objective  To investigate the factors influencing setup errors in prostate cancer patients receiving radiotherapy under the guidance of fan-beam computed tomography (FBCT) images.
    Methods  A retrospective analysis was conducted on 24 prostate cancer patients treated with volumetric modulated arc therapy at the Third Hospital of Peking University from May 2024 to March 2025, comprising a total of 25 treatment sessions. A total of 600 FBCT image sets were collected. Rigid registration was used to match and calibrate the errors for each FBCT session. The setup errors were recorded in the vertical (VRT), longitudinal (LNG), and lateral (LAT) directions, as well as the rotational errors in yaw, pitch, and roll. The bladder and rectal volumes were automatically segmented and recorded. A linear regression model was employed to analyze the relationship between setup errors and patient age, height, weight, BMI, bladder volume, and rectal volume.
    Results  After image-guided correction via rigid registration, the couch calibration values in the VRT, LNG, and LAT directions were (0.16±0.53) cm, (0.06±0.70) cm, and (0.21±0.51) cm, respectively. The rotational calibration values in the yaw, pitch, and roll directions were (−0.17±1.38)°, (0.39±1.44)°, and (−0.05±1.02)°, respectively. Significant positive correlations were observed between VRT errors and age, height, weight, and rectal volume. LNG errors showed significant negative correlations with weight and BMI but a positive correlation with rectal volume. LAT errors were positively correlated with age and bladder volume and negatively correlated with height. Yaw errors were positively correlated with age, weight, and BMI. Pitch errors were negatively correlated with age, height, and weight but positively correlated with bladder volume. Roll errors were positively correlated with age, height, and rectal volume. Bladder volume gradually decreased as treatment fractions progressed (β=−2.893, P < 0.001), while rectal volume showed no significant change (β=0.118, P=0.162).
    Conclusion  Key factors positively correlated with setup errors include age, rectal volume, and BMI, while height and weight showed negative correlations. Reduced bladder filling capacity was observed over the treatment course. Setup errors result from the combined effects of multiple factors.

     

/